Standard

ALTERNATE REFRIGERANT CONSISTENCY CRITERIA FOR USE IN MOBILE AIR CONDITIONING SYSTEMS

1993-06-01
HISTORICAL
J1658_199306
This SAE Recommended Practice applies to refrigerant blends (multicomponent refrigerants) intended for use as retrofit refrigerants to replace CFC-12 (R12) in mobile air conditioning systems. Since the composition of non-azeotropic refrigerant mixtures changes as refrigerant is lost, either through the vapor phase or the liquid phase, the method of charging air conditioning systems is important. The purpose of this document is to determine the proper refrigerant phase, liquid or vapor, for system charging by relating system performance changes to the charging method. This document is complete only when combined with the requirements of SAE J1657.
Standard

RATING CRITERIA FOR ELECTRONIC REFRIGERANT LEAK DETECTORS

1993-06-01
HISTORICAL
J1627_199306
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air conditioning systems. This document does not address any safety issues concerning their design or use.
Standard

SERVICE HOSE FOR AUTOMOTIVE AIR CONDITIONING

1992-06-02
HISTORICAL
J2196_199206
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air-conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
Standard

SAFETY AND CONTAINMENT OF REFRIGERANT FOR MECHANICAL VAPOR COMPRESSION SYSTEMS USED FOR MOBILE AIR-CONDITIONING SYSTEMS

1991-11-01
HISTORICAL
J639_199111
This SAE Recommended Practice is restricted to mechanical vapor compression refrigerant systems driven by the vehicle or auxiliary engine, which provides cooling for the passenger compartment. This document provides guidelines for refrigerant containment and safety for a mobile air-conditioning system. It is not intended to restrict the use of, or further development of, other types of refrigeration systems for passenger compartment cooling. Should other systems be found practical at some future time, this document may be amended or an additional recommended safety practice drawn up for such other systems.
Standard

STANDARD OF PURITY FOR USE IN MOBILE AIR-CONDITIONING SYSTEMS

1989-10-01
HISTORICAL
J1991_198910
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically seated, rigid pipe are not covered in this document.